List of product documentations :

Interface Units for analog signals

  • INT-AI-SUBD : 8 channels - Analog Input (4-20mA) 2, 4 wires. SUBD25 connector for connection with DCS or PLC.
  • INT-AI-HE10-ST : 8 channels - Analog Input (4-20mA) 2, 4 wires. HE10-16 connector for connection with DCS or PLC. Screw terminals for process signals connection
  • INT-AI-F-SUBD : 8 channels - Analog Input (4-20mA) 2, 4 wires with fuse (100mA). SUBD25 connector for connection with DCS or PLC. Screw terminals for process signals connection
  • INT-AI-F-HE10 : 8 channels - Analog Input (4-20mA) 2, 4 wires with fuse (100mA). HE10-16 connector for connection with DCS or PLC. Screw terminals for process signals connection
  • INT-AI-4W-F-SUBD : 8 channels - Analog Input For (4-20mA) 4 wires or 1-5V with fuse (50mA). SUBD25 connector for connection with DCS or PLC. Screw terminals for process signals connection
  • INT-AI-4W-F-HE10 : 8 channels - Analog Input For (4-20mA) 4 wires or 1-5V with fuse (50mA). HE10-16 connector for connection with DCS or PLC. Screw terminals for process signals connection
  • INT-AI-8CH-ISO : 8 channels - Isolated Analog Input. (4-20mA) 2,4 wires for standard or smart (HART protocol) transmitters. 1-5Vdc. SUBD25 or HE10-16 connector for connection with DCS or PLC
  • INT-AO-SUBD : 8 channels - Analog Output (4-20mA). SUBD25 connector for connection with DCS or PLC.
  • INT-AO-HE10-ST : 8 channels - Analog Output (4-20mA). HE10-16 connector for connection with DCS or PLC. Screw terminals for process signals connection.
  • INT-AO-F-SUBD : 8 channels - Analog Output (4-20mA) with fuse (50mA). SUBD connector for connection with DCS or PLC. Screw terminals for process signals connection
  • INT-AO-F-HE10 : 8 channels - Analog Output (4-20mA) with fuse. HE10-16 connector for connection with DCS or PLC. Screw terminals for process signals connection
  • INT-AO-8CH-ISO : 8 channels - Isolated Analog Output. (4-20mA) for standard or smart (HART protocol) valve transmitters. 1-5Vdc. SUBD25 or HE10-16 connector for connection with DCS or PLC
  • INT-AI-16CH : 16 channels - Analog Input (4-20mA) 2, 4 wires. SUBD37 connector for connection with DCS or PLC.
  • INT-32FUSES-ALARM : 32 channels termination panel with monitored fuses and alarm contact retransmission

Interface units for discrete signals

  • INT-DI1-SUBD : 8 channels - Discrete Input. Interface unit for non-isolated inputs (24Vdc provided by the input card). SUBD25 connector for connection with the DCS or PLC. Screw terminals for process signals connection
  • INT-DI1-HE10 : 8 channels - Discrete Input. Interface unit for non-isolated inputs (24Vdc provided by the input card). HE10-16 connector for connection with DCS or PLC. Screw terminals for process signals connection
  • INT-DI2-SUBD : 8 channels - Discrete Input. Interface unit for isolated inputs (24Vdc provided by an external power supply). SUBD25 connector for connection with the DCS or PLC. Screw terminals for process signals connection
  • INT-DI2-HE10 : 8 channels - Discrete Input. Interface unit for isolated inputs (24Vdc provided by an external power supply). HE10-16 connector for connection with the DCS or PLC. Screw terminals for process signals connection
  • INT-DI8-SUBD : 8 channels - Discrete Input. Interface unit for direct inputs Without fuse and relay. SUBD25 connector for connection with the DCS or PLC.
  • INT-DI8-HE10 : 8 channels - Discrete Input. Interface unit for direct inputs Without fuse and relay. HE10-16 connector for connection with the DCS or PLC.
  • INT-DI8-PCI : 8 channels - Pulse Input Interface unit. SUBD25 connector for connection with DCS or PLC
  • INT-DI8-ISO24DC : 8 channels - Isolated Discrete Input Interface unit SUBD25 connector for connection with DCS or PLC
  • INT-DO8-DIR-SUBD : 8 channels - Discrete output without fuse and without relay - Direct output. SUBD25 connector for DCS or PLC conenction
  • INT-DO8-DIR-HE10 : 8 channels - Discrete output without fuse and without relay - Direct output. HE1016 connector for DCS or PLC conenction
  • INT-DO8F-DIR-SUBD : 8 channels - Discrete output with fuse (2A) and without relay - Direct output. SUBD15 connector for DCS or PLC conenction
  • INT-DO8F-DIR-HE10 : 8 channels - Discrete output with fuse (2A) and without relay - Direct output. HE1016 connector for DCS or PLC conenction
  • INT-DO8R-SUBD : 8 channels - Discrete output with relay. SUBD15 connector for connection with the DCS or PLC
  • INT-DO8-R-HE10 : 8 channels - Discrete output with relay. HE1016 connector for connection with the DCS or PLC
  • INT-DO8RF : 8 channels - Discrete output with relay and fuse protection (5A). SUBD15 and HE1016 connector for connection with the DCS or PLC.
  • 1/4 INT-DO32-R-ST : 8 channels > (1/4 x 32 channels) - Discrete output relay. Standard or Solid State relay. Screw terminals for process signal connection. HE10-16 connector for connection with the DCS or PLC
  • 1/4 INT-DO32-R-CCT : 8 channels > (1/4 x 32 channels) - Discrete output relay. Standard or Solid State relay. Cage clamp terminals for process signal connection. HE10-16 connector for connection with the DCS or PLC
  • 1/4 INT-DO32-R-F-ST : 8 channels > (1/4 x 32 channels) - Discrete output relay. Channel by Channel fuse protection. Fuse 5A for electromechanical relay and 2A solid state relay. Standard or Solid State relay. Screw terminals for process signal connection. SUBD37 connector for
  • 1/4 INT-DO32-R-F-CCT : 8 channels > (1/4 x 32 channels) - Discrete output relay. Standard or Solid State relay. Channel by Channel fuse protection. Fuse 5A for electromechanical relay and 2A solid state relay. Cage clamp terminals for process signal connection. SUBD37 connector
  • FC508-1 : 8 channels - Discrete output. With relays and terminals allowing dry contact integration connected in series (ie : integration of safety dry contact with the command comming from DCS). Relay control signal using screw terminals
  • FC508-2 : 8 channels - Discrete output. With relays and terminals allowing dry contact integration connected in series (ie : integration of safety dry contact with the command comming from DCS). Relay control signal using SUBD25 connector
  • INT-DI16-SOE : 16 Channels - Discrete Input - Sequence of Events Interface unit. SUBD37 connector for connection with the DCS or PLC
  • INT-DI162-F : 16 Channels - Discrete Input
  • INT-DO-16-RA-ST : 16 channels - Discrete output relay. Standard or Solid State relay. Local Power Supply (optionnal) failure indicated on terminal (relay). Screw terminals for process signal connection. SUBD25 connector for connection with the DCS or PLC
  • INT-DO-16-RA-CCT : 16 channels - Discrete output relay. Standard or Solid State relay. Local Power Supply (optionnal) failure indicated on terminal (relay). Cage clamp terminals for process signal connection. SUBD25 connector for connection with the DCS or PLC
  • INT-DO16-R-1-ST : 16 channels - Discrete output relay. Standard or Solid State relay. Option -1 for sourcing discrete output modules (the DCS or PLC output module provides the current to the interface unit on each line). Screw terminals for process signal connection. SUBD2
  • INT-DO16-R-1-CCT : 16 channels - Discrete output relay. Standard or Solid State relay. Option -1 for sourcing discrete output modules (the DCS or PLC output module provides the current to the interface unit on each line). Cage clamp terminals for process signal connection.
  • INT-DO16-R-2-ST : 16 channels - Discrete output relay. Standard or Solid State relay. Option -2 for sinking discrete output modules (the DCS or PLC output module receives the current from the interface unit on each line). Screw terminals for process signal connection. SUBD
  • INT-DO16-R-2-CCT : 16 channels - Discrete output relay. Standard or Solid State relay. Option -2 for sinking discrete output modules (the DCS or PLC output module receives the current from the interface unit on each line). Cage clamp terminals for process signal connection.
  • INT-DI322 : 32 Channels - Discrete Input - Dry contact. SUBD37 connector for connection with the DCS or PLC
  • INT-DI322-F : 32 Channels - Discrete Input - Dry contact with fuse (250mA). SUBD37 connector for connection with the DCS or PLC
  • INT-DI322-PROX : 32 Channels - Discrete Input. Proximity switch or dry contact. SUBD37 connector for connection with the DCS or PLC
  • INT-DI323 : 32 Channels - Discrete Input. Proximity detector. SUBD37 connector for connection with the DCS or PLC
  • INT-DI323F : 32 Channels - Discrete Input. Proximity detector with fuse protection (250mA). SUBD37 connector for connection with the DCS or PLC
  • INT-DI32-ISO24DC : 32 Channels - Discrete isolated input. Dry contact or proximity detector - Input powered by 24Vdc. SUBD37 connector for connection with the DCS or PLC
  • INT-DI32-ISO48DC : 32 Channels - Discrete isolated input - Dry contact or proximity detector - Input powered by 48Vdc. SUBD37 connector for connection with the DCS or PLC
  • INT-DI32-ISO48AC : 32 Channels - Discrete isolated input. Dry contact or proximity detector - Input powered by 48Vac. SUBD37 connector for connection with the DCS or PLC
  • INT-DI32-ISO120AC : 32 Channels - Discrete isolated input. Dry contact or proximity detector - Input powered by 120Vac. SUBD37 connector for connection with the DCS or PLC
  • INT-DI32-ISO230AC : 32 channels - Discrete isolated input. Dry contact or proximity detector - Input powered by 230Vac. SUBD37 connector for connection with the DCS or PLC
  • INT-DI323-ISO24DC : 32 channels - Discrete isolated input. Dry contact or proximity detector - Input powered by 24Vdc. SUBD37 connector for connection with the DCS or PLC
  • INT-DI323-ISO24DC-R : 32 channels - Discrete isolated input. Dry contact or proximity detector - Input powered by redundant 24Vdc. SUBD37 connector for connection with the DCS or PLC
  • INT-DI323-ISO48DC : 32 channels - Discrete isolated input. Dry contact or proximity detector - Input powered by 48Vdc. SUBD37 connector for connection with the DCS or PLC
  • INT-DI323-ISO48DC-R : 32 channels - Discrete isolated input. Dry contact or proximity detector - Input powered by redundant 48Vdc. SUBD37 connector for connection with the DCS or PLC
  • INT-DO32-DIR : 32 channels - Discrete output - Direct output. SUBD37 connector for connection with the DCS or PLC
  • INT-DO32-F-DIR : 32 channels - Discrete output. Direct output with fuse protection (500mA). SUBD37 connector for connection with the DCS or PLC
  • INT-DO32-R-ST : 32 channels - Discrete output relay. Standard or Solid State relay. Screw terminals for process signal connection. SUBD37 connector for connection with the DCS or PLC
  • INT-DO32-R-CCT : 32 channels - Discrete output relay. Standard or Solid State relay. Cage clamp terminals for process signal connection. SUBD37 connector for connection with the DCS or PLC
  • INT-DO32-R-F-ST : 32 channels - Discrete output relay. Channel by Channel fuse protection. Fuse 5A for electromechanical relay and 2A solid state relay. Standard or Solid State relay. Screw terminals for process signal connection. SUBD37 connector for connection with the DCS or PLC
  • INT-DO32-R-F-CCT : 32 channels - Discrete output relay. Standard or Solid State relay. Channel by Channel fuse protection. Fuse 5A for electromechanical relay and 2A solid state relay. Cage clamp terminals for process signal connection. SUBD37 connector for connection with the DCS or PLC
  • INT-32FUSES-ALARM : 32 channels termination panel with monitored fuses and alarm contact retransmission

Interface units for intrinsically safe (Ex) signals

  • INT-DO-IS : 4 channels - I.S. Discrete Output. ATEX certified (Ex). Interface unit for discrete signals towards an hazardous area. To be installed in safe area. To be connected to an I.S. discrete output card. SUBD25 connector for connection with DCS or PLC. Screw t
  • INT-ANALOG-IS : 8 channels - I.S. Analog Input (4-20mA), 2 wires. ATEX certified (Ex). Interface unit for analog signals comming from an hazardous area. To be installed in safe area. To be connected to an I.S. analog input card. SUBD25 connector for connection with DCS
  • INT-DI-IS : 16 channels - I.S. Discrete Input. ATEX certified (Ex). Interface unit for discrete signals comming from an hazardous area. To be installed in safe area. To be connected to an I.S. discrete input card. SUBD25 connector for connection with DCS or PLC. Scr

Mounting and wiring panels for conditioning modules for standard signals

  • FCSOC : Individual socket for DIN rail mounting of FC series modules
  • FC8308-1 : Mounting panel for input/output modules - 8 slots - FC series - Redundant Power Supply
  • FC8308-2 : Mounting panel for input/output modules - 8 slots - FC series - Redundant Power Supply
  • FC5321 : Mounting panel for input modules - FC series. For 16 modules
  • FC8316-1 : Mounting panel for input/output modules - 16 slots - FC series - Redundant Power Supply
  • FC5331 : Mounting panel for output modules - FC series. For 16 modules
  • 1/2 x FC8308-2 : Mounting panel for input/output modules - 8 slots - FC series - Redundant Power Supply

Mounting and wiring panels for conditioning modules for intrinsically safe (Ex) signals

  • FI301 : Mounting panel for 8 input modules - FI series (Ex).
  • FI308-1 : Mounting panel for 8 input modules - FI series (Ex).
  • 1/2 x FI316-2 : Mounting panel for 16 input modules - FI series (Ex).
  • FI316-1 : Mounting panel for 16 input modules - FI series (Ex).
  • FI316-2 : Mounting panel for 16 input modules - FI series (Ex).
  • CL6321-2 : Mounting panel for input modules. For 16 modules : 50184, 51184.
  • CL6331-2 : Mounting panel for output modules. For 16 modules : 51202H.

Mounting and wiring panels for conditioning modules for (SIL3-IEC61508) safety signals

  • FS-61508-M412 : Termination panel for safety circuit. SIL3 - IEC61508 Approved. 4 conditioned - 12 direct channels
  • FS-61508-M88 : Termination panel for safety circuit. SIL3 - IEC61508 Approved. 8 conditioned - 8 direct channels
  • FS-61508-M124 : Termination panel for safety circuit. SIL3 - IEC61508 Approved. 12 conditioned - 4 direct channels
  • FS-61508-16 : Termination panel for safety circuit. SIL3 - IEC61508 Approved. 16 conditioned
  • FSSOC : Individual socket for DIN rail mounting of FS series modules
  • INT-61508 : Remote termination panel. SIL3 - IEC61508 Approved. 16 channels

Conditioning modules for standard signals

  • FC0181 : 1 channel - Temperature converter. Input : Thermocouple or mV. Output : 4-20mA
  • FC0181-L : 1 channel - Temperature converter with linearization. Input : Thermocouple or mV. Output : 4-20mA
  • FC0182 : 1 channel - Temperature converter. Input : RTD or potentiometer. Output : 4-20mA
  • FC0184 : 1 channel - Repeater power supply. Input : 4-20mA. Output : 4-20mA. For 2, 3 or 4 wires standard or HART transmitters
  • 50184-A1 : 1 channel - Galvanic isolating module for standard or smart transmitters. -A1 : Power supply : 24 Vdc. -BN : Without socket. Input options :. -C1 : 1 - 5V. -C2 : 4 - 20mA. -C3 : 0 - 20mA. C* : Special range : Consult us HART options :. -DN : HART signal filtering -D1 : HART signal passthrough
  • 50184-A2 : 1 channel - Galvanic isolating module for standard or smart transmitters. -A2 : Power supply : 48 Vdc. -BN : Without socket. Input options :. -C1 : 1 - 5V. -C2 : 4 - 20mA. -C3 : 0 - 20mA. C* : Special range : Consult us HART options :. -DN : HART signal filtering -D1 : HART signal passthrough
  • FIR0184 : 1 channel - Galvanic isolating module. For standard / smart transmitters or valve controller. -A1 : Power supply 24Vdc. -A2 : Power supply 48Vdc. Input options : -C1 : 1 - 5V. -C2 : 4 - 20mA. -C3 : 0 - 20mA. -C* : Special range : Consult us HART options : -DN : HART signal filtering. -D1 : HART signal passthroug. Output options :. -E1 : 0 - 10Vdc. -E2 : 1 - 5Vdc. -E3 : 4 - 20mA. -E4 : 0 - 20mA. -E* : Special range
  • FC0202 : 1 channel - Isolating driver. Input : 4-20mA. Output : 4-20mA. For valve positioner.
  • FC0202-LFD : 1 channel - Isolating driver. Input : 4-20mA. Output : 4-20mA. With Line Fault Detection reported to the DCS or PLC. For valve positioner.
  • FC0203 : 1 channel - Isolating driver. Input : 0-20mA. Output : 4-20mA. For valve positioner.
  • FO10800 : Optic < -- > Electric conversion module.
  • FC2184 : 2 channels - Repeater power supply. Input : 4-20mA. Output : 4-20mA. For 2, 3 or 4 wires standard or HART transmitters
  • FC2185 : 2 channels - Repeater power supply. Input : 0-20mA. Output : 4-20mA. For 2, 3 or 4 wires standard or HART transmitters
  • FC2186 : 2 channels - Conversion module. Input : 0-10V. Output : 4-20mA. For 2, 3 or 4 wires standard or HART transmitters
  • FC2187 : 2 channels - Convertion module. Input : 1-5V. Output : 4-20mA. For 2, 3 or 4 wires standard or HART transmitters
  • FC2190 : 2 channels - Converter module. Input : 0-1A DC. Output : 4-20mA.

Conditioning modules for intrinsically safe (Ex) signals

  • FI322 : 1 channel - Analog input (Ex). Repeater power supply 4-20mA. For 2, 3 or 4 wire standard or HART transmitters
  • FI324 : 1 channel - Analog input (Ex). Temperature converter. RTD or potentiometer input
  • FI325 : 1 channel - Analog input (Ex). Temperature converter. Thermocouple or mV input
  • 51184-A1 : 1 channel - Analog input (Ex). Repeater power supply 4-20mA. For 2, 3 or 4 wire standard or HART transmitters. -A1 : Power supply : 24 Vdc. -BN : Without socket. Input options :. -C1 : 1 - 5V. -C2 : 4 - 20mA. -C3 : 0 - 20mA. C* : Special range : Consult us HART options :. -DN : HART signal filtering Output options :. -F1 : 0 - 10Vdc -F2 : 1 - 5Vdc -F3 : 4 - 20mA -F* : special range
  • 51184-A2 : 1 channel - Analog input (Ex). Repeater power supply 4-20mA. For 2, 3 or 4 wire standard or HART transmitters. -A2 : Power supply : 48 Vdc. -BN : Without socket. Input options :. -C1 : 1 - 5V. -C2 : 4 - 20mA. -C3 : 0 - 20mA. C* : Special range : Consult us HART options :. -DN : HART signal filtering Output options :. -F1 : 0 - 10Vdc -F2 : 1 - 5Vdc -F3 : 4 - 20mA -F* : special range
  • FI332 : 1 channel - Analog output (Ex). Isolating driver. For standard or HART valve positionner
  • 51202H-A1 : 1 channel - Analog output (Ex). Isolating driver. For standard or HART valve positionner. -A1 : Power supply : 24 Vdc. -BN : Without socket. Input / Output options :. -C1 : Input 4 - 20mA , Output 4 - 20mA. -C2 : Input 4 - 20mA , Output 0 - 20mA. -C3 : Input 0 - 20mA , Output 4 - 20mA. -C4 : Input 0 - 20mA , Output 0 - 20mA. -C5 : Input 0 - 10Vdc , Output 4 - 20mA. -C6 : Input 0 - 10Vdc , Output 0 - 20mA. -C7 : Input 1 - 5Vdc , Output 4 - 20mA. -C8 : Input 1 - 5Vdc , Output 0 - 20mA. -C* : Speci
  • 51202H-A2 : 1 channel - Analog output (Ex). Isolating driver. For standard or HART valve positionner. -A2 : Power supply : 48 Vdc. -BN : Without socket. Input / Output options :. -C1 : Input 4 - 20mA , Output 4 - 20mA. -C2 : Input 4 - 20mA , Output 0 - 20mA. -C3 : Input 0 - 20mA , Output 4 - 20mA. -C4 : Input 0 - 20mA , Output 0 - 20mA. -C5 : Input 0 - 10Vdc , Output 4 - 20mA. -C6 : Input 0 - 10Vdc , Output 0 - 20mA. -C7 : Input 1 - 5Vdc , Output 4 - 20mA. -C8 : Input 1 - 5Vdc , Output 0 - 20mA. -C* : Speci
  • FI303 : 1 channel - Discrete output (Ex). Isolating solenoid driver.
  • FC322 : 1 channel - Analog input (Ex). Repeater power supply 4-20mA. For 2, 3 or 4 wire standard or HART transmitters
  • FC332 : 1 channel - Analog output (Ex). Isolating driver. For standard or HART valve positionner
  • FI302-T : 2 channels - Discrete input (Ex). Dry contact - Proximity detector. Solid state output
  • FI302-R : 2 channels - Discrete input (Ex). Dry contact - Proximity detector. Relay output

Conditioning modules for safety signals (SIL3 - IEC1508)

  • FS323 : 1 channel - Safety Isolated Analog Input module. SIL3 - IEC61508 Approved. (4-20mA) 2, 4 wires
  • FS301-A : 1 channel - Safety Isolated Discrete Input module. SIL3 - IEC61508 Approved. Module working with a normally open contact, the contact closes in Alarm mode
  • FS301-S : 1 channel - Safety Isolated Discrete Input module. SIL3 - IEC61508 Approved. Module working with a normally closed contact, the contact opens in Safety mode
  • FS303 : 1 channel - Safety SIL3-IEC61508 relay module. SIL3 - IEC61508 Approved. For Energize To Trip functionality (ETT), with line fault monitoring
  • FS303-INV : 1 channel - Safety relay module. SIL3 - IEC61508 Approved. For Inverted Energize To Trip functionality (ETT), with line fault monitoring
  • FS304 : 1 channel - Safety SIL3-IEC61508 relay module. SIL3 - IEC61508 Approved. For De-energize To Trip functionality (DTT)

Wiring adapters for quick connection / disconnection

  • ADP-HE1016/SUBD25M : 8 channels - Wiring adapter module for Input / Output. For quick connection between a system and a marshalling cabinet
  • ADP-SUBD37M/SUBD37M : 16 or 32 channels - Wiring adapter module for Input / Output. For quick connection between a system and a marshalling cabinet

Wiring adapter for system migration

  • CIA-PAR02 : Hartmann & Braun Contronic-P Interface adapter for migration toward DeltaV. AO 1 channel CONTRONIC-P cable (PAR01) / 8ch DeltaV AO card. DO 1 channel CONTRONIC-P cable (PAR02) / 8ch DeltaV DO card
  • CIA-PEB03 : Hartmann & Braun Contronic-P Interface adapter for migration toward DeltaV. DI 30 channel CONTRONIC-P cable / 32ch DeltaV DI card
  • CIA-PEB03-ISO : Hartmann & Braun Contronic-P Interface adapter for migration toward DeltaV. DI 30 channel CONTRONIC-P cable (Isolated signals) / 32ch DeltaV DI card
  • CIA-PEB63Ex + CBL-612 + FI316 + 15xFI302 : Hartmann & Braun Contronic-P Interface adapter for migration toward DeltaV. DI 30 channel CONTRONIC-P cable (Ex signals) / 32ch DeltaV DI card
  • CIA-PEA01 : Hartmann & Braun Contronic-P Interface adapter for migration toward DeltaV. AI 4 channel CONTRONIC-P cable / 1/2 x 8ch DeltaV AI card
  • CIA-PAA02 : Hartmann & Braun Contronic-P Interface adapter for migration toward DeltaV. AO 3/4 channel CONTRONIC-P cable (PAA01or PAA02) / 8ch DeltaV AO card
  • CIA-PEA02 : Hartmann & Braun Contronic-P Interface adapter for migration toward DeltaV. AI 4 channel CONTRONIC-P cable / 8ch DeltaV AI card or 1/2 x 16ch DeltaV AI card
  • PIA-AO-8 : Serie 20 Provox Interface Adapter for migration toward DeltaV. AO 8ch Provox Panel / 8ch AO DeltaV card
  • PIA-2PULSE-4 : Serie 20 Provox Interface Adapter for migration toward DeltaV. PCI 8ch Provox Panel / 2 x 4ch Multifunction DeltaV card
  • ADP-S202 + CBL-688 + FC8308 + 8xFC2184 : CEGELEC C350-C370 Interface adapter for migration toward DeltaV. AI 8 channel CEGELEC cable / 16ch DeltaV AI card + isolating modules for galvanic isolation
  • ADP-S234 : CEGELEC C350-C370 Interface adapter for migration toward DeltaV. A0 8 channel CEGELEC cable / 8ch DeltaV AO card
  • ADP-S152 : CEGELEC C350-C370 Interface adapter for migration toward DeltaV. DO 8 channel CEGELEC cable / 1 x 8ch DeltaV DO card
  • ADP-S416 : CEGELEC C350-C370 Interface adapter for migration toward DeltaV. PCI 8 channel CEGELEC cable / 2 x 4ch DeltaV Multifunction card
  • CIA-PEB02 : Hartmann & Braun Contronic-P Interface adapter for migration toward DeltaV. DI 15 channel CONTRONIC-P cable (PEB01or PEB02) / 1/2 x 32ch DeltaV DI card
  • CIA-PEB02-ISO : Hartmann & Braun Contronic-P Interface adapter for migration toward DeltaV. DI 15 channel CONTRONIC-P cable (Isolated signals) / 1/2 x 32ch DeltaV DI card
  • CIA-PAB02ER : Hartmann & Braun Contronic-P Interface adapter for migration toward DeltaV. DO 15 channel CONTRONIC-P cable (Isolated signals by relays) ) / 1/2 x 32ch DeltaV DO card
  • CIA-PEB62-Ex : Hartmann & Braun Contronic-P Interface adapter for migration toward DeltaV. DI 15 channel CONTRONIC-P cable (Ex signals) ) / 1 x 16ch IS DeltaV DI card
  • ADP-S201 : CEGELEC C350-C370 Interface adapter for migration toward DeltaV. AI 15 channel CEGELEC cable / 16ch DeltaV AI card
  • PIA-2AI-8 : Serie 20 Provox Interface Adapter for migration toward DeltaV. AI 16ch Provox Panel / 2 x 8ch AI DeltaV card
  • PIA-AI-16 : Serie 20 Provox Interface Adapter for migration toward DeltaV. AI 16ch Provox Panel / 16ch AI DeltaV card
  • PIA-2DI-8 : Serie 20 Provox Interface Adapter for migration toward DeltaV. DI 16ch Provox Panel / 2 x 8ch DI DeltaV card
  • PIA-DI-16 : Serie 20 Provox Interface Adapter for migration toward DeltaV. DI 16ch Provox Panel / 1/2 x 32ch DeltaV card
  • PIA-2DO-8 : Serie 20 Provox Interface Adapter for migration toward DeltaV. DO 16ch Provox Panel / 2 x 8ch DeltaV card
  • PIA-DO-16 : Serie 20 Provox Interface Adapter for migration toward DeltaV. DO 16ch Provox Panel / 32ch DeltaV card
  • PIA-DI-DO-16 : Serie 20 Provox Interface Adapter for migration toward DeltaV. Mixed DI/DO 16ch Provox Panel / 1/2 X 32ch DI/DO DeltaV card
  • ADP-S215 + CBL-829 + FC8308 + 8xFC2184 : CEGELEC C350-C370 Interface adapter for migration toward DeltaV. AI 16 channel CEGELEC cable / 16ch DeltaV AI card + isolating modules for galvanic isolation
  • ADP-S101 : CEGELEC C350-C370 Interface adapter for migration toward DeltaV. DI 16 channel CEGELEC cable / 1/2 x 32ch DeltaV DI card
  • ADP-S151 : CEGELEC C350-C370 Interface adapter for migration toward DeltaV. DO 16 channel CEGELEC cable / 1/2 x 32ch DeltaV DO card
  • ADP-S160 : CEGELEC C350-C370 Interface adapter for migration toward DeltaV. DO 16 channel CEGELEC cable / 1/2 x 32ch DeltaV DO card

Racks and accessories

  • BC10499 : File for DeltaV I/O carrier mounting in 19" cabinet
  • BC10689 : File for Migartion adapters and DeltaV I/O carrier mounting in 19" cabinet
  • BC10726 : File for Migration adapters and DeltaV I/O carrier mounting in 19" cabinet

Spare parts

Remote termination interface units

  • INT-162a-SUBD : Remote interface unit SUBD25 male connector 8 double row terminals (16 terminals)
  • INT-322a-SUBD : Remote interface unit SUBD37 male connector 16 double row terminals (32 terminals)
  • INT-322b-SUBD : Remote interface unit SUBD37 female connector 16 double row terminals (32 terminals)